skip to Main Content

DMP 331

$350.00

Industrial Pressure Transmitter for Low Pressure

Stainless Steel Sensor

  • accuracy according to IEC 60770:
  • standard: 0.35 % FSO
  • option: 0.25 / 0.1 % FSO

The pressure transmitter DMP 331 can be used in all industrial areas when the medium is compatible with stainless steel 1.4404 (316 L) or 1.4435 (316 L). Additional are different elastomer seals as well as a helium tested welded version available.

The modulare concept of the device allows to combine different stainless steel sensors and electronic modules with a variety of electrical and mechanical versions.Thus a diversity of variations is created, meeting almost all requirements in industrial applications

Preferred areas of use are

  • Plant and machine engineering
  • Environmental engineering (water – sewage – recycling)
  • Energy industry

Data Sheet DB_DMP331_E

Stock Available

SKU: DMP 331 110-1000-1-5- 100-200-1-00 Category:

Input pressure range

Nominal pressure gauge [bar] -1…0 0.10 0.16 0.25 0.40 0.60 1 1.6
Nominal pressure abs. [bar] 0.40 0.60 1 1.6
Overpressure [bar] 5 0.5 1 1 2 5 5 10
Burst pressure ≥ [bar 7.5 1.5 1.5 1.5 3 7.5 7.5 15
Nominal pressure gauge / abs. [bar] 2.5 4 6 10 16 25 40 60
Overpressure [bar] 10 20 40 40 80 80 105 105
Burst pressure ≥ [bar] 15 25 50 50 120 120 210 210
Vacuum resistance
pN ≥ 1 bar: unlimited vacuum resistance
pN < 1 bar: on request

Output signal / Supply

Standard 2-wire: 4…20 mA VS = 8…32 VDC
SIL-version: VS = 14…28 VDC
Option IS-protection 2-wire: 4…20 mA VS = 10…28 VDC
SIL-version: VS = 14…28 VDC
Options 3-wire
3-wire:
0…20 mA VS = 14…30 VDC
0…10 V VS = 14…30 VDC

Performance

Accuracy1
standard:
nominal pressure < 0.4 bar: ≤ ≤ ± 0.50 % FSO
nominal pressure ≥ 0.4 bar: ≤ ± 0.35 % FSO
option 1: ≤ ± 0.25 % FSO
option 2: nominal pressure ≥ 0.4 bar: ≤ ± 0.10 % FSO
Permissible load
current 2-wire: Rmax = [(VS – VS min) / 0.02 A] Ω
current 3-wire: Rmax = 240 Ω
voltage 3-wire: Rmin = 10 kΩ
Influence effects
supply: 0.05 % FSO / 10 V
load: 0.05 % FSO / kΩ
Long term stability ≤ ± 0.1 % FSO / year at reference conditions
Response time
2-wire: ≤ 10 msec
3-wire: ≤ 3 msec

1accuracy according to IEC 60770 – limit point adjustment (non-linearity, hysteresis, repeatability)

Thermal effects (offset and span)

Nominal pressure pN [bar] -1…0 < 0.40 ≥ 0.40
Tolerance band [% FSO] ≤ ± 0.75 ≤ ± 1 ≤ ± 0.75
in compensated range [°C] -20…85 0…70 -20…85

Permissible temperatures

Medium -40…125 °C
Electronics / environment -40…85 °C
Storage -40…100 °C

Electrical protection

Short-circuit protection permanent
Reverse polarity protection
no damage, but also no function
Electromagnetic compatibility
emission and immunity according to EN 61326

Mechanical stability

Vibration 10 g RMS (25…2000 Hz)
according to DIN EN 60068-2-6
Shock 500 g / 1 msec
according to DIN EN 60068-2-27

Materials

Pressure port stainless steel 1.4404 (316 L)
Housing stainless steel 1.4404 (316 L)
Option compact field housing s
stainless steel 1.4301 (304)
cable gland M12x1.5, brass, nickel plated (clamping range 2 … 8 mm)
Seals
standard: FKM
options:
EPDM
welded version2 (for pN ≤ 40 bar)
others on request

2welded version only with pressure ports according to EN 837, pN ≤ 40 bar

Explosion protection (only for 4…20 mA / 2-wire)

Approvals DX19-DMP 331
IBExU 10 ATEX 1068 X / IECEx IBE 12.0027X
zone 0: II 1G Ex ia IIC T4 Ga
zone 20: II 1D Ex ia IIIC T135 °C Da
Safety technical maximum values
Ui = 28 V, Ii = 93 mA, Pi = 660 mW, Ci ≈ 0 nF, Li ≈ 0 μH,
the supply connections have an inner capacity of max. 27 nF to the housing
Permissible temperatures for environment
in zone 0: -20…60 °C with patm 0.8 bar up to 1.1 bar
in zone 0: -20…60 °C with patm 0.8 bar up to 1.1 bar
Connecting cables (by factory)
cable capacitance: signal line/shield also signal line/signal line: 160 pF/m
cable inductance: signal line/shield also signal line/signal line: 1 μH/m

Miscellaneous

Option SIL2 version3 according to IEC 61508 / IEC 61511
Current consumption
signal output current: max. 25 mA
signal output voltage: max. 7 mA
Weight approx. 200 g
Installation position any4
Operational life 100 million load cycles
CE-conformity EMC Directive: 2014/30/EU
ATEX Directive 2014/34/EU

3only for 4…20 mA / 2-wire, not in combination with accuracy 0.1 %

4Pressure transmitters are calibrated in a vertical position with the pressure connection down. If this position is changed on installation there can be slight
deviations in the zero point for pressure ranges pN ≤ 1 bar.

Back To Top